Select a type

Choose a fan to view options.

Looking for accessories?

Eveything you need for your Triangle product.

Shop Accessories
Select an application

Choose an application to view options.

Looking for accessories?

Everything you need for your Triangle product.

Shop Accessories
Additional Resources

Downloads, FAQs, and more.

Frequently Asked Questions View all FAQs
How do you order the correct replacement parts?

Before ordering replacement parts, make sure you have the fan model and serial number.

Where can I find instructions to wire a motor on my fan?

The nameplate of the motor includes a wiring diagram. Wiring diagrams can also be found beneath the motor image in our Buy Parts section. Simply click the wiring diagram icon to view it.

Can I install a thermostat?

Yes, but only if the thermostat has a simple on/off operation. Please note: if the thermostat varies the amount of voltage delivered, it will damage the motor and void the warranty.

Can I install my whole house fan vertically?

Comfort Cooler (CC) series whole-house fans may be mounted vertically, however, the AS and CSS shutters will not function properly in the vertical position. We do not carry a ceiling shutter for vertical installation. Vertical installation instructions.

Quality Products

Download our latest product catalog.

Download
VI Series Industrial Wall-Mounted Exhaust Fans

QUALITYProducts.
SINCE 1948.

VI Series Industrial Wall-Mounted Exhaust Fans

The Go-To Industrial Exhaust Fan for Reliable Ventilation

Since 1948, Triangle Engineering has specialized in rugged ventilation solutions that stand up to the harshest industrial settings. The VI Series is our belt-drive, wall-mounted exhaust fan, carefully designed to draw out heated, contaminated, or stale air from demanding work environments. By removing airborne pollutants and reducing heat buildup, these fans help you maintain better air quality and a safer, more productive facility.


Key Features & Benefits

  1. Belt-drive operation
    The VI Series utilizes a belt-drive system for reliable, efficient air movement. Models with open drip proof (ODP) or totally enclosed (TE) motors up to 1.5 hp include an automatic belt tensioner for reduced maintenance.
  2. Robust wall-mounted design
    Engineered for installation on an exterior wall, these exhaust fans pull interior air out of your facility, creating negative pressure for consistent ventilation and improved air quality.
  3. Simplified maintenance
    Belts, motors, and pulleys can be accessed from inside the building, minimizing downtime and labor costs. There is no need for exterior lifts or complex procedures.
  4. Adaptable motor & voltage options
    Choose from 1/3 hp up to 5 hp in open drip proof (ODP), totally enclosed (TE), or hazardous location (HL) motors. Standard voltages include 115V or 230V (single-phase) and 230V or 460V (three-phase). Additional options such as 277V, 208V, 415V, or 575V are also available upon request.
  5. Integrated galvanized wall box
    Each VI model arrives with a factory-installed galvanized steel wall box, offering a straightforward mounting process on any exterior wall. This setup streamlines installation and saves valuable time.
  6. Rolled inlet venturi
    Each VI fan features a rolled inlet venturi finished with a durable polyester powder coat, helping improve overall airflow efficiency while withstanding tough industrial conditions.
  7. Ships fully assembled & tested
    Every fan leaves our factory fully assembled and rigorously tested, speeding up on-site setup so you can get up and running quickly.

Technical Specifications

  • Blade diameters: 24″, 30″, 36″, 42″, 48″, 54″, 60″
  • Motor horsepower: from 1/3 hp up to 5 hp
    • Standard increments typically include 1/3, 1/2, 3/4, 1, 1.5, 2, 3, and 5 hp (other sizes may be available upon request)
  • Motor enclosure: available in ODP, TE, or HL
  • Automatic belt tensioner: included on ODP or TE models up to 1.5 hp
  • Standard voltages:
    • Single-phase: 115V, 230V
    • Three-phase: 230V, 460V
      (Additional options: 277V, 208V, 415V, 575V)
  • Drive access: belts, pulleys, and motor are serviceable from inside the building
  • Fully assembled & factory-tested: ready for immediate installation and operation
  • Construction: built with sturdy, industrial-grade materials and maintenance-friendly details to ensure reliable performance in tough environments
  • Ambient temperature rating: suitable for applications up to 110°F. If your operation regularly exceeds 110°F, please contact us about higher ambient temperature motors.
  • Performance data: airflow capacities range from approximately 4,190 CFM up to 41,000 CFM. For detailed performance at various static pressures, see the Triangle Engineering product catalog.

Available Accessories

Triangle Engineering offers a full line of accessories to complement VI Series exhaust fans, ensuring an optimal installation for your unique application. The following add-ons can be tailored to meet specific environmental and operational needs:

  • Rainhoods
    Provide a protective cover against exterior elements, keeping critical fan components dry.
  • Guards
    Enclose moving parts to safeguard personnel and equipment.
  • Shutters/Dampers
    Offered in standard sizes or custom increments (as small as 1/8″) to fit your opening. They regulate airflow, limit backdraft, and maintain optimal building pressure when the fan is off.

Ideal Use Cases

  • Manufacturing & Industrial Facilities: Remove fumes, dust, and excess heat from production lines or workstations.
  • Warehouses & Storage Areas: Keep interior conditions more comfortable by venting out stale, hot air.
  • Automotive & Aerospace Workshops: Extract hazardous fumes or chemical vapors, improving workspace safety.
  • Food & Beverage Processing: Manage humidity, steam, and odor control while supporting food safety standards.
  • Heavy Equipment & Foundry Operations: Exhaust hot air and metal fumes to protect personnel and equipment.
  • Large Commercial Buildings: Vent out accumulated heat and odors, improving indoor air quality for employees and customers.

Why VI Series?

  1. Reliability and durability
    Built in the USA with a blend of domestic and foreign components, Triangle Engineering has been an industry leader since 1948. We construct the VI Series to tackle challenging industrial exhaust applications.
  2. Simple maintenance
    Service belts, motors, and pulleys from inside the building to avoid the need for exterior lifts or complex procedures.
  3. Optimized workplace conditions
    Exhausting hot, stale, or contaminated air helps stabilize interior temperatures and improve air quality, promoting safety and comfort.
  4. Flexible motor choices
    With horsepower options spanning 1/3 hp to 5 hp, plus open drip proof (ODP), totally enclosed (TE), or hazardous location (HL) enclosures, there’s a configuration for every industrial exhaust requirement.
  5. Balanced airflow with supply fan
    For ideal indoor air quality, consider pairing your VI Series exhaust fan with a Triangle Engineering supply fan. This balanced approach helps replace exhausted air with fresh intake air, maintaining proper building pressure and ensuring optimal ventilation throughout your facility.

Why Choose Triangle Engineering?

A Legacy of Quality Since 1948

For more than seven decades, we have specialized in crafting top-tier ventilation products that stand up to demanding industrial environments. Our fans are factory-assembled, rigorously tested, and supported by an experienced customer service team.

Customized Solutions Available

Not seeing exactly what you need? We can customize our VI Series exhaust fans to meet your specific airflow requirements, unique motor setups, specialized construction or non-standard materials like stainless steel or aluminum. Contact us to learn how we can optimize your industrial exhaust needs.


Related Products

  • V Series: Belt-drive commercial duty panel exhaust fans
  • VID Series: Direct-drive wall mount cabinet exhaust fans
  • FHI Series: Severe duty panel exhaust fan for harsh or high-temperature environments

Get Your VI Fan Today

Don’t let stagnant or contaminated air hinder operations. The VI Series industrial exhaust fan delivers robust airflow to help you maintain a cleaner, safer work environment, no matter how demanding your application may be.

Ready to enhance your facility’s ventilation? Request a quote or contact us to learn more about the VI Series and discover how it can transform your workspace.

Details

  • Bronze powder coated rolled inlet venturi for efficient airflow
  • Rugged heavy gauge galvanized housing
  • Available in sizes from 24” to 60” blade diameter
  • Available with ODP, TE and HL motors
  • Belt drive
  • Optional Two-speed, 115V single-phase 1/3 and 1/2HP motors

See full specifications for sizing and performance data

View Full Specs

Hazardous Location Models

Hazardous location models are made to order and are not returnable.

  • No wiring
  • Non-sparking aluminum blades
  • Stationary motor mounts
  • Belt drive: single speed, Div. I, Class I, Group D & Class II, Groups F & G