MCMS Series Medium Stand ManCooler
The MCMS Series Medium Stand ManCooler is engineered with a heavy-duty pivoting cradle that allows controlled directional airflow in demanding industrial environments. Designed for facilities where airflow must be redirected across changing work zones, the MCMS delivers high velocity industrial air movement with precise discharge control.
Available in diameters from 18 inches to 48 inches with horsepower ranging from 1/4 HP to 10 HP, the MCMS moves up to 49,700 CFM. The medium stand elevates the discharge point above floor level while the barrel pivots within the cradle to reposition airflow without moving the base.
Built with reinforced steel construction and direct-drive reliability, the MCMS is designed for continuous duty operation in manufacturing plants, fabrication shops, and heavy industrial facilities.
Pivoting air delivery
Heavy-duty cradle design allows airflow direction to be adjusted within the frame. Ideal for adapting airflow to work areas and equipment layouts.
Elevated discharge height
Medium stand configuration positions airflow above floor level for improved coverage of standing operators and production areas.
Directional industrial airflow
Redirect high velocity air where it is needed without moving the entire unit. Helps reduce stagnant zones and improve airflow efficiency.
Direct-drive industrial reliability
The propeller mounts directly to the motor shaft, eliminating belts and routine tension adjustments. Fewer moving components reduce maintenance and downtime.
High-efficiency cast aluminum airfoil propellers
Precision-balanced blades deliver strong air velocity and extended throw while protecting the motor from overload.
OSHA compliant guards
Heavy-duty guards provide worker protection.
Heavy-duty welded steel construction
Thick-gauge barrel and reinforced pivot frame are built to withstand industrial handling and continuous operation.
TE and Hazardous Location motor options
Available with Totally Enclosed (TE) and Hazardous Location (HL) motors in single-phase and three-phase configurations.
Integrated lifting eye
Standard lifting eye allows safe hoisting and repositioning within large facilities.
Factory assembled and tested
Each MCMS unit is fully assembled and tested prior to shipment to ensure performance and durability.
Sizes and Performance
Standard Blade Diameters:
18 inches, 24 inches, 30 inches, 36 inches, 42 inches, 48 inches
Airflow Capacity:
Up to 49,700 CFM
RPM Options:
1140 RPM and 1750 RPM configurations depending on model (consult factory for different speed configurations)
Propeller Type:
High-efficiency cast aluminum airfoil blades
Motor Types, Voltages & Horsepower
Motor Types:
- Totally Enclosed (TE)
- Hazardous Location (HL)
Horsepower Range:
1/4 HP through 10 HP (consult factory for different HP sizes)
Standard Voltages:
Single Phase: 115V, 230V
Three Phase: 230V, 460V
Additional voltages and configurations available upon request.
Construction & Finish
- Heavy Duty cradle construction
- Heavy-gauge steel barrel construction
- Welded rolled angle rings
- Direct-drive configuration
- OSHA compliant guards
- Integrated lifting eye
- Polyester powder coat finish
- Industrial duty motor options
Certain MCMS Series ManCoolers are available with Hazardous Location (HL) motor packages.
Hazardous location models are built to order and are non-returnable.
Standard Configuration for Hazardous Location Models
All hazardous location model fans include the following:
- No factory wiring
- Aluminum blades
- Stationary motor mounts
- Explosion-proof motor rated as specified at time of order
Motor ratings for hazardous location configurations are as follows:
Belt Drive Models:
Single Speed, Division I, Class I Group D and Class II Groups F & G
Direct Drive Models:
Single Speed, Division I, Class I Group D and Class II Groups F & G
It is the responsibility of the purchaser and specifying authority to determine proper classification and suitability for the intended installation.
Important Safety Notice
Hazardous location models are supplied with explosion-proof motors and aluminum blades. The hazardous rating applies to the motor only.
The overall finished fan assembly is not represented as certified for hazardous atmospheres.
Application, installation, and wiring must comply with all applicable local, state, and national electrical codes and must be performed by a qualified electrician.
Hazardous location motors cannot be operated into service factor. As a result, fan performance may be slightly lower than published standard ratings.
These units are not suitable for applications where combustible residue, including paint accumulation, may collect on the motor or blade.
Triangle Engineering does not determine site classification or suitability for hazardous locations. Final responsibility for proper equipment selection rests with the purchaser and specifying authority.
The MCMS Series is designed for facilities requiring directional, high velocity airflow in dynamic industrial environments.
Multi-Operator Workstations
Redirect airflow across large assembly areas as cooling needs shift between personnel.
Welding Bays and Fabrication Areas
Aim airflow toward active work zones to help manage radiant heat.
Conveyor Lines and Packaging Operations
Elevated discharge height improves coverage along production lines.
Maintenance Areas and Platforms
Adjust airflow direction to suit changing service positions.
Equipment Banks and Machinery Cooling
Target airflow toward motors, compressors, or process equipment without relocating the fan base.
Loading Docks and Industrial Staging Areas
Modify airflow direction as door positions and traffic patterns change.
Directional airflow control
Unlike fixed-discharge industrial floor fans, the MCMS allows directional airflow control within the cradle frame.
Designed for changing work environments
Ideal for facilities where equipment layout or personnel positions shift throughout the day.
High velocity industrial performance
Engineered to project strong airflow across mid-level work zones.
Reduced maintenance
Direct-drive configuration eliminates belt service requirements.
Industrial-grade construction
Heavy steel components and reinforced pivot assembly withstand demanding plant-floor conditions.
Made in the USA
Made in the USA with domestic and global components to maintain quality control and lead time reliability.
Backed by decades of ventilation expertise
Triangle Engineering has supplied industrial air movement equipment to heavy industry since 1948.
Every facility presents unique airflow challenges. The MCMS Series can be configured to meet specific operational and environmental requirements.
Performance tuning
Select horsepower and RPM configurations to match airflow targets.
Hazardous location configurations
Explosion-proof motor packages available for classified environments.
Specialty coatings
Custom finishes for corrosive, chemical, or coastal applications.
Voltage and frequency options
50 Hz and specialty voltage configurations available for domestic and international projects.
Application-specific modifications
Frame adjustments and accessory integration available upon request.
Details
- Direct drive
- Durable polyester powder coat finish
- Single-phase or three-phase models available with TE or HL motors
- OSHA approved spiral wound guards
- Airfoil propellers
See full specifications for sizing and performance data
View Full SpecsHazardous Location Models
Hazardous location models are made to order and are not returnable.
- 18" - 36" single and three phase motor options. 42" - 48" three phase only
- Spark resistant aluminum blades
- Stationary motor mount
- No wiring